39
SW 838023
GB Shuttle Manual 100316
Appendix
9090
6060
3030
0
-40
-30
-20
-10
dB
Standard Range Version/FM Approved
Shuttle
®
Ultrasonic Sensor Types 200640 / 200641
Measuring range 12 m (liquids), 6 m (solids)
Frequency 40 KHz
Spread 7 °
Dead band 35 cm
Sensitivity See figure below
Temperature - 20 to + 60 °C
Materials VALOX
Cable 200640:
Cable 200641:
Shielded, insuated with oil resistant PVC,
length 12 m.
Shielded, insuated with oil resistant PVC,
length 50 m
(Max. 100 m with 690010 cable)
Enclosure IP 68, water-proof, withstands sub-
merging, max. 1 bar
CE approvals EN 50081-1, EN 50082-1
Ex approvals FM Class 1, Div. 1, Group A-G